Dimensions
  • D: 13mm
  • H: 12mm
  • W: 62 mm
Technical specification

Power supply mode

DC 12V

Output

NC contact type

Current

0.20A

Panel material

ABS plastic

Product color

White

Operating Temperature °C

-20°C ~ +80℃

Operating Temperature °F

-4°F - +176 °F

Alarm triggering distance

20.00mm

Safety features

Tamper alarm, Disconnection alarm, Door status detection

Wiring
  1. Connect the COM terminal of the sensor to a +12V supply.
  2. Connect the NO (Normally Open) terminal to a digital input on the controller (e.g., IN1).
  3. Connect the GND terminal of the controller to the sensor's ground line to complete the circuit.
Magnetic contact sensor setup via App
  1. Choose Controller
    1. Tap on the Controller that you would like to add new I/O to.
    2. To edit the I/O, click on the Controller to which the I/O is added.
  1. Add button for Inputs
    1. Inputs tab is selected.
    2. List of Inputs is shown.
    3. In order to add new Input tap on the Add button.
  1. Choose type - Inputs
    1. From the list that is shown tap on the desired I/O that you would like to add.
  1. New Magnet Contact sensor
    1. Fill the following form:
    2. Name - Write the name of the Magnet sensor.
      1. Role - Choose Role from the list.
      2. Group - Choose Group from the list. Group is a group of I/O and scenarios that seems most logical to you.
      3. Pin - Choose Pin from the list. Pin is physical place on the Controller where I/O is connected to it.
      4. Photo - Choose photo for the Magnet sensor.
      5. Identifier - This field is the identifier of the I/O in the electrical project.
      6. Advanced - You can choose type of the signal that activates or tiggers the Magnet sensor: rising, falling, change, change inverted.
      7. Timeout - It is the duration for which the Magnet Contact  sensor will remain Open in auto mode.
    3. When you want to confirm your choice tap Save and Submit.
  1. Select Roles - Inputs
    1. Tap in the field Roles.
    2. Select checkbox/checkboxes (for multiple choice) next to the Role/Roles that you would like to choose.
    3. To confirm selection tap the button Save/Done.
  1. Select Groups - Inputs
    1. In this step you should select Group.
    2. Select check box/check boxes next to the desired Group/Groups from the list.
    3. When you want to confirm your choice tap button Done/Save.
  1. Change Photo
    1. Tap on the photo of the Magnet Contact  sensor.
    2. You have three options:
      1. Open Library - The phone’s Library will open.
      2. Open Camera - You can take a picture using your smartphone.
      3. Choose default image - These images are prepared in advance in order  to provide a complete and seamless experience.
  1. Choose PIn
    1. Tap on the radio button next to the Pin that you would like to choose.
    2. To confirm selection tap on Save/Done.
  1. Advanced - Magnet Contact sensor
    1. Tap radio button next to the type of signal that you would like to choose.
    2. You can choose:
      1. Rising
      2. Falling
      3. Change
      4. Change inverted
    3. You can choose type of the signal that activates or triggers the Magnet Contact sensor.