Hot Tub with Massage Jets

Updated: 7 Sep 2025
Tags
Humidity/Temperature/Brightness
On/Off
Open/close valve
Temperature
Wired
Description

Pierre provides advanced automation and control options for spa baths and hydrotherapy pools, ensuring a seamless and luxurious experience. Here’s a detailed breakdown of the features offered:

 

1. Water Flow and Jet Control:

Control valves for hydrotherapy jets and water circulation, allowing users to precisely manage water pressure and flow for a tailored relaxation experience.

2. Temperature Control:

Monitor and adjust the water temperature in real time, ensuring that the spa bath or hydrotherapy pool maintains the perfect temperature.

Remote control of heating systems to regulate water temperature as needed.

3. Lighting Control:

Full control of lighting within and around the spa, allowing users to create the desired ambiance.

Set automated schedules or manually adjust lighting to suit the mood.

4. Valve Automation:

Automate the operation of valves controlling specific water features like massage jets, offering full flexibility and convenience.

5. Energy Efficiency:

Pierre’s energy-saving capabilities optimize the usage of jets and heating systems, reducing energy consumption while maintaining comfort.

6. Customization and Automation:

Create personalized automations and scenarios to control jets, lights, or temperature settings based on time or environmental factors.

7. Control Options:

Manage all features through the Pierre app on smartphones or tablets, either locally via a display or remotely over the internet, providing easy access from anywhere.

 

These features ensure that Pierre offers a complete, efficient, and customizable solution for managing spa baths and hydrotherapy pools

Schemes
Hot tub with massage jets - Wiring | 1. Contactor, 2. Circulation Pump, 3. Lamp, 4. Heat Pump, 5. Temperature Sensor - Electric schemes
Images
Hot tub with massage jets - Wiring in PIERRE
Cables
Position Wires Diameter Type Comment
From PIERRE to Relay board 2 0.75 mm² PF GND, OUTPUT
From Relay Board to Contractor 2 1.5 mm² PP NO, COM
From Contactor to Circulation Pump 2 2.5 mm² NYM-J L , N 230V
From Relay board to Light 2 1.5 mm² PP/Y L, N
From Contactor to Heat Pump 2 2.5 mm² NYM-J L , N 230V
From Temperature sensor to PIERRE 3 cat.5 UTP +5V, GND, SIGNAL
From Buttons to PIERRE input 2 0.75 mm² PF +12V, SIGNAL
What you need